0098 1600A Air Circuit Breaker 3p 400V Fixed Type

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Energy-storage Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (26)
  • 0098 1600A Air Circuit Breaker 3p 400V Fixed Type
  • 0098 1600A Air Circuit Breaker 3p 400V Fixed Type
  • 0098 1600A Air Circuit Breaker 3p 400V Fixed Type
  • 0098 1600A Air Circuit Breaker 3p 400V Fixed Type
  • 0098 1600A Air Circuit Breaker 3p 400V Fixed Type
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
SJKW1-1600
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Draw out / Fixed
Structure
ACB
Poles Number
3p/4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
ISO9001-2000, CE, CCC
Rated Current
200-1600A
Ue(V)
400/415, 660/690
Frequency
50/60Hz
Transport Package
Wooden Cases
Trademark
JCHKO
Origin
Zhejiang, China
HS Code
8536200000
Production Capacity
1000 Unit/Units Per Week

Product Description

Product Description
Premium SJKW11600 Type 3P/4P Circuit Breaker at Best Prices
    
      The SJKW1-1600 universal circuit breaker is one of the new circuit breakers developed with advanced technology. This product is suitable for general power distribution systems, new energy distribution systems, multi-level power grids, etc. These devices are deployed at the grid-connected ends of DC power supply and generation terminals as protection bandwidth, featuring isolation function, compact size, high breaking capacity, and multiple functions.
Rated operational voltage: AC400V / 690V
Rated frequency: 50 Hz
Rated current: 200A~1600A
Adjustable connection switching
Selectivity category: Class B
Implementation standard: GB/T14048.2-2008
Compliance standards: IEC60947-1 and GB/T14048.1-2012 (General rules for low-voltage switchgear and controlgear)
IEC60947-2 and GB/T14048.1-2008 (Circuit-breakers for low-voltage switchgear and controlgear)
IEC60947-4-1 and GB/T14048.4 (Electromechanical contactors and motor-starters including motor protection)
0098 1600A Air Circuit Breaker 3p 400V Fixed Type
Normal Service and Installation Conditions
   Ambient air temperature: -5°C to +40°C (derating required beyond this range), with 24-hour average not exceeding +35°C
   Installation altitude not exceeding 2000m, derating required above 2000m
   Relative humidity at installation site should not exceed 50% at maximum temperature of +40°C, and can be higher at lower temperatures (e.g., up to 90% at 20°C). Occasional condensation due to temperature changes should be considered.
   Pollution degree: Level 3
   Main circuit installation category: IV; Auxiliary and control circuit installation category: II
   The circuit breaker should be installed in locations free from explosion hazards, conductive dust, rain/snow intrusion, and conditions that could corrode metals or damage insulation.
Main Technical Specifications
Model
SJKW1-1600
Frame rating current Inm(A)
1600
Rated current In(A)
200,400,500,630,800,1000,1250,1600
Rated operational voltage Ue(V)
AC400,AC690
Operational frequency(Hz)
50Hz/60Hz
Rated insulation voltage Ui(V)
1000
Rated impulse withstand voltage Uimp(kV)
12
Power frequency withstand voltage U(V) for 1min
3500
Number of poles
3/4
Neutral pole rated current In(A)
100%In
Selectivity category
GB/T14048.2
B
Ultimate short-circuit breaking capacity Icu(kA)(RMS)
AC400V
65
AC690V
50
Service short-circuit breaking capacity Ics(kA)(RMS)
AC400V
55
AC690V
42
Rated short-circuit making capacity Icm(kA)(peak)
AC400V
143
AC690V
105
Rated short-time withstand current (1s)lcw(kA)(RMS)
AC400V
55
AC690V
42
Total breaking time (without additional delay)(ms)
25
Closing time(ms)
Max 70
Electrical Life(Time)
AC400V
In=200A~630A
1500
In=800A~1250A
1000
In=1600A
800
AC690V
In=200A~630A
1000
In=800A-1250A
650
In=1600A
500
Mechanical Life(Time)
maintenance-free
15000
Under maintenance
20000
Dimensions(W×H×D)
mm
Fixed Type
3P
260×310×240
Draw-out Type
3P
275×345×330
4P
330×310×240
4P
345×345×330
0098 1600A Air Circuit Breaker 3p 400V Fixed Type
0098 1600A Air Circuit Breaker 3p 400V Fixed Type
0098 1600A Air Circuit Breaker 3p 400V Fixed Type
Company Profile
0098 1600A Air Circuit Breaker 3p 400V Fixed Type
0098 1600A Air Circuit Breaker 3p 400V Fixed Type
FAQ
Could I have prices of your produets?
Welcome. Pls feel free to send us an email here.You will get our reply in 24 hours.
Can we print our logo/webiste/company name on products?
Yes, please advise the size and Pantone Code of the logo.
What's the lead time for regular order?
7-15 days for order quantity Iower than 1000pc;For more quantity,usualy 20 days.
Do you inspect the finished products?
Yes,each step of production and fnished products will be came out inspection by QC department before shipping.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier