0044 Customizable 2000A Circuit Breaker Solutions IP65 Protected

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Energy-storage Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (26)
  • 0044 Customizable 2000A Circuit Breaker Solutions IP65 Protected
  • 0044 Customizable 2000A Circuit Breaker Solutions IP65 Protected
  • 0044 Customizable 2000A Circuit Breaker Solutions IP65 Protected
  • 0044 Customizable 2000A Circuit Breaker Solutions IP65 Protected
  • 0044 Customizable 2000A Circuit Breaker Solutions IP65 Protected
  • 0044 Customizable 2000A Circuit Breaker Solutions IP65 Protected
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
SJKW1-2000
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Draw out / Fixed
Structure
ACB
Poles Number
3p/4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
ISO9001-2000, CE, CCC
Rated Current
630~2000A
Ue(V)
400/415, 660/690
Frequency
50/60Hz
Transport Package
Wooden Cases
Specification
50.00cm * 40.00cm * 50.00cm
Trademark
JCHKO
Origin
Zhejiang, China
HS Code
8536200000
Production Capacity
1000 Unit/Units Per Week

Product Description

Product Description
 Customizable 2000A Circuit Breaker Solutions  IP65 Protected 
    The SJKW1 series intelligent universal circuit breaker (hereinafter referred to as the circuit breaker) is designed for use in distribution networks with an AC frequency of 50 Hz, a rated voltage up to 660 V (or 690 V), and a rated current ranging from 200 A to 6300 A. It is capable of distributing electrical energy while providing protection against faults such as overload, undervoltage, short circuit, and single-phase grounding. The circuit breaker features intelligent protection functions and precise selective protection capabilities, which enhance the reliability of power supply and prevent unnecessary power outages. Additionally, it is equipped with an open communication interface that supports "four remote" operations, thereby meeting the requirements of control centers and automation systems. The circuit breaker is suitable for installation at altitudes up to 2000 meters, with a pulse withstand voltage of 8000 V (adjusted according to the relevant standards for different altitudes, with the maximum value not exceeding 12000 V). In configurations without an intelligent controller or sensor, the circuit breaker can function as an isolator. 
    This product complies with international and national standards, including GB14048.2 "Low-voltage Switchgear and Controlgear - Low-Voltage Circuit Breakers" and IEC60947-2 "Low-Voltage Switchgear and Controlgear - Circuit Breakers."
0044 Customizable 2000A Circuit Breaker Solutions IP65 Protected
General
    
    The universal frame circuit breaker 2000 series is a high-current protection device used in low-voltage distribution systems, with a rated current typically ranging from 1600A to 2000A. It is suitable for use as main switches or critical branch protection in power distribution systems. This circuit breaker is available in two mounting configurations: withdrawable type and fixed type, and comes in both 3-pole (3P) and 4-pole (4P) specifications.
  The withdrawable design facilitates maintenance and replacement, featuring three operational positions: "Connected/Test/Isolated" for safe operation without power interruption. The fixed-type structure is simple, directly installed in distribution cabinets at lower cost, though maintenance requires power shutdown for disassembly.
   3P circuit breakers are suitable for three-phase three-wire systems (such as motor-driven power loads), while 4P circuit breakers are designed for three-phase four-wire systems (including neutral line, applicable for mixed power and lighting loads), providing more comprehensive protection.
   Featuring high breaking capacity (typically above 65kA), these circuit breakers support intelligent trip units for overload, short-circuit, and ground fault protection. They can be equipped with motorized operating mechanisms and communication modules (such as Modbus), making them ideal for industrial, commercial building, and data center applications.
0044 Customizable 2000A Circuit Breaker Solutions IP65 Protected
Type  designation
1.Classification:
a.By installation method: a. Fixed type b. Drawer type;
b.By operation method: a. Electrical operation b. Manual operation (for maintenance and servicing).
2.Rated current in scope of frame size:
2000 Type In:630A,800A,1000A,1250A,1600A,2000A
3.Types of releases:
Intelligent controller, Undervoltage instantaneous (or time-delay) release, Shunt release;
4.Intelligent controller performance: 
    Intelligent controller is divided into: H type (for communication), M type (standard intelligent), L type (economic);
a.Has long-time delay inverse time-delay overload, short-time delay inverse time-delay, fixed time-delay, instantaneous functions which can be set by the user to form the required protection characteristics;
b.Single-phase grounding protection function;
c.Display function: Setting current display, tripping current display, main display of each line voltage (voltage display should be specified when ordering);
d.Alarm function: Overload alarm;
e. Self-check function: Overheating self-check, microcomputer self-diagnosis (optional);
f.Test function: Test the operating characteristics of the controller.
5.Common use accessory:
a.Shunt release-AC220V/230V,AC380V/400V,DC220V,DC110V
b.Undervoltage release-AC220V/230V,AC380V/400V, it is classified to instantaneous type and time-delay type.
c.Closing electromagnetic AC220V/230V,AC380V/400V,DC220V,DC110V
d.Motor-driven energy-storage mechanism-AC220V/230V,AC380V/400V,DC220V,DC110V
e.Auxiliary contact-4a4b,2a6b,3a3b
Note: a-normal open, b-normal close
6.Optional accessory:
a.Mechanical interlock;
b.One circuit breaker (1lock+1key)
c.Two circuit breaker(steel cable interlock, connecting rod interlock,2lock+1key)
d.Three circuit breaker(3lock+2keys, connecting rod interlock)
e.Automatic power transfer system
f.Current transformer connected with neutral lead
Introduction to Structure
Front indication of circuit breaker
0044 Customizable 2000A Circuit Breaker Solutions IP65 Protected
0044 Customizable 2000A Circuit Breaker Solutions IP65 Protected
Operating conditions
Item
Description
Ambient temperature
-5℃~+40℃;the average value within 24h shall not exceed+35℃
L type and M type controller can be used under-40℃~+70℃
Altitude
≤2000m
Pollution grade
3
Safety category
Main circuit and undervoltage tripping coil is IV,
other auxiliary and control circuit is Ⅲ
Installation position
Vertical installed,inclination between the mounting plane and the vertical plane
should not exceed±5°
Company Profile
0044 Customizable 2000A Circuit Breaker Solutions IP65 Protected
FAQ
Q: What are the typical applications for your air circuit breakers?
How do I select the right size (current rating) ACB for my application?
 How do I ensure the ACB has sufficient breaking capacity (Icu/Ics) for my system?
A: Our ACBs are widely used as main incoming feeders, couplers, and large outgoing feeders in:
Industrial power distribution systems (factories, plants)
Commercial buildings (data centers, hospitals, shopping malls, hotels)
Infrastructure projects (ports, airports, power stations, substations)
Marine and offshore installations (if applicable, mention specific certifications)
Renewable energy systems (solar farms, wind farms).
A: Selecting the correct current rating involves:
Calculating the total maximum continuous load current of the circuit.
Applying relevant derating factors (ambient temperature, enclosure, grouping).
Choosing an ACB with a Rated Current (In) equal to or higher than the calculated value. We strongly recommend consulting with our technical team to ensure optimal selection based on your specific load profile and system requirements.
A: The ACB's Ultimate Breaking Capacity (Icu) must be equal to or greater than the prospective short-circuit current at its installation point in your electrical network. This requires a short-circuit study of your system. We can provide guidance based on typical system levels or review your specific data.
Technical Data and Performance
This street light features high brightness, energy saving, environmental protection, and easy installation. It has a waterproof rating of IP67 and has passed CE certification. It is suitable for schools, parks, roadsides, factories, squares, etc. It has a warranty period of 3 years. Moreover, we can provide various styles to meet your needs.